Hashrate
1.35 Ph/s
Power
20000W
Efficiency
14814.81 W/PH
Availability
Out of stock
Product overview
Built for reliable commercial mining
Specifications Manufacturer MicroBT Model WhatsMiner M79S Release Dec 2025 Noise level 50dB Cooling Hydro cooling Power 20000W Interface Ethernet Temperature 5 - 45 °C Humidity 5 - 95 %
Tested & certified
Prepared and checked before delivery
Global delivery
Shipping support to more than 50 countries
Managed hosting
Power, cooling, monitoring, and operations support
24/7 assistance
Sales, delivery, hosting, and after-sales help
Profitability
Estimated operating economics
Review estimated revenue, electricity cost, net result, and payback timing alongside the machine price and power profile.
Net Profit / Day
$7.77
Last updated: Nov 28, 2026, 12:23 AM
Gross Revenue / Day
$38.2
Estimated before deductions.
Electricity / Day
$28.8
20000W at $0.0600/kWh.
Net Profit / Day
$7.77
Estimated after costs.
Pool Fee
$0.76
2%
Hosting Commission
$0.86
10%
Monthly Net
$233.1
30-day estimate
Yearly Net
$2,836.05
365-day estimate
ROI Estimate
4.3 years
Based on net/day
Mining Coin
QUAI
Calculator target
Data Source
WhatToMine
Profit feed
Status
Profitable
Profit category
Profit data is temporarily delayed
Live profitability figures are temporarily unavailable. We’re showing the most recent estimate.
Last available profit
$7.77/day
Last updated
Nov 28, 2026, 12:23 AM
Installation check
Can I run this miner?
Check the electrical, heat, noise, and uptime requirements for MicroBT WhatsMiner M79S (1.35Ph/s). This is a planning estimate; a qualified electrician should approve the final installation.
Assessment
Changes are recommended before installation
Hosted mining or a purpose-built mining space is the safer option for this setup.
Total load
20,000 W
Current draw
90.9 A
Recommended breaker
125 A
Monthly energy
14,400 kWh
Monthly power cost
$1,728.00
Heat output
68,240 BTU/h
Estimated noise
50 dB
Operating location
Not selected
What to address
- Available 20A supply is below the recommended 125A dedicated circuit.
- The selected cooling setup may not remove the heat produced safely.
- This setup is likely unsuitable for normal living space because of heat, noise, and power demand.
PDU: 220V PDU rated above 125A
Cable: Industrial cable and protection sized for at least 125A
Cooling: Exhaust heat directly outdoors and keep intake air clean and unrestricted.
Machine Assurance Report
Inspection, condition, and warranty details
Review machine condition, warranty, inspection status, test results, availability notes, and report photos before purchase.
Condition
New
Availability
In Stock
Warranty
180 days
Inspection Date
Jan 3, 2026
Power Test
Passed
Hashrate Test
Passed
Noise
50 dB
Packaging
Inspected
Deployment fit
Evaluate this machine against your operating target
Consider this miner if its algorithm, power draw, hashrate, and estimated payback profile match your mining plan.
Hosting
Deploy through Rocket Crypto managed hosting
Hosting is useful if you do not want to manage power, heat, noise, cooling, uptime monitoring, and physical maintenance yourself.
Operating assumptions
Understand the variables behind the estimate
Profit estimates help compare ASIC miners using the available machine data and market assumptions.